Incoming receipt
Check part number, quantity, lot and packing list, then scan into stock.
Every chip fully inspected before release
From 100% visual inspection of incoming parts and X-Ray imaging to electrical spot tests and final release, every batch keeps a fully archived, traceable inspection record, backed by our ISO 9001 quality system.
Certification
ISO 9001 certification is not a certificate hanging on the wall. It is a quality system written into every step of our workflow.
System Certificate
Quality Management System
Scope: electronic component distribution and outbound inspection
Annual surveillance audit / recertification every 3 years
Every inspection step maps to a controlled revision of its work instruction and record form. Inspectors work from the sheet, and conclusions follow the acceptance criteria, never personal experience.
A full-process internal audit runs every year, and management reviews system effectiveness alongside it. Any nonconformity needs a corrective action submitted and verified to closure.
Credentials come before price: factory authorization, agency chain and historical batch performance all go on file. A failed annual review removes the supplier from the approved list immediately.
Inspection records, micrographs, X-Ray images and reports are archived by part number and lot for at least 3 years. On any claim, the full evidence chain is retrievable within 24 hours.
QC Process
Six gates, not one skipped. No batch enters the shipping queue until every step is complete and recorded on file.
Check part number, quantity, lot and packing list, then scan into stock.
Original packaging, desiccant, humidity card and date code all match.
100% check under 30-60x scope: marking, leads, oxidation, resurfacing.
X-Ray structure and XRF plating analysis against golden samples.
Key parameters validated on the test board per datasheet, data kept.
QA sign-off, shipped with inspection report and CoC.
Testing Capability
Our own test bench works alongside accredited third-party laboratories, covering appearance, structure, material and electrical performance. When independent endorsement is required, the partner lab issues the report directly.
Non-destructive imaging
Composition and thickness
Decap, die marking check
Wetting assessment
Key parameters validated
Accredited lab reports